Factory Outlets VQ Series Double Pump Wholesale to Frankfurt

Factory Outlets VQ Series  Double Pump Wholesale to Frankfurt Featured Image
Loading...

Short Description:

  Product Introduction The High-pressure and high-performance Intra-vane pumps for Mobile Equipmen Features 1.To adopt balanced hydraulic for the structure of Intra-vane and ten –Vane design, higher pressure, top to 21 MPa.2.To adopt floating structure for side plate, it will do a compensation for end-face clearance by automatic, so that even the pump under high pressure it can maintain a high volumetric efficiency. 3.The side plate is made of dual-metal material, it improved ...


Product Detail

Product Tags

Related Video

Feedback (2)

With our leading technology at the same time as our spirit of innovation,mutual cooperation, benefits and development, we are going to build a prosperous future alongside one another with your esteemed enterprise for Oil Pump Dispenser, Single Vane Pump, Hydraulic Fluid Power Pump, We hope we can have a friendly relationship with businessman from all over the world.
Factory Outlets VQ Series Double Pump Wholesale to Frankfurt Detail:

 

Product Introduction

The High-pressure and high-performance Intra-vane pumps for Mobile Equipmen

Features

1.To adopt balanced hydraulic for the structure of Intra-vane and ten –Vane design, higher pressure, top to 21 MPa.
2.To adopt floating structure for side plate, it will do a compensation for end-face clearance by automatic, so that even the pump under high pressure it can maintain a high volumetric efficiency.
3.The side plate is made of dual-metal material, it improved the seizure resistance, and so that the life of pump will be longer.

VQ Series Double Pump

NO. Part Qty NO. Part Qty NO. Part Qty
1 Straight Key  1 7 Cir Clip For   Shaft  1 13 Rear Cartridge  1
2 Shaft 1 8 Pile Type   Retainer  1 14 O Ring  1
3 Front Cover  1 9 O Ring  1 15 Rear Cartridge  1
4 Shaft Seal  1 10 Front Cartridge  1 16 Hexagon Headed   Bolt  4
5 Gasket  1 11 Body  1
6 Ball Bearing  1 12 Hexagon Headed   Bolt  4

Model Designation

(F3-) 3525V  38 A 17 -1 AB 22 R
Note  Series ▼ Flow-Shaft end pump Port 
connection 
▼ Flow-cover 

end pump

Shaft type  Outlet
 Position 
Design 
number 
Rotation 
No-marking: 

Petroleum series oil

emulsification fluid

water glycol-fluid
F3:

phosphate
ester fluid 

2520V 10、12、14、15、17、
19、21、25
A-SAE
A-SAE 4-bolt flange
2、3、4、5、6、7、8、9、10、11、12、14 1-Str key
86-HD Str key
11-Spline
See below  22 (Views from shaft end of pump)
R-right hand for clockwise 
L-left hand for counter-clockwise
3520V 21、25、30、32、35、
38、45
2、3、4、5、6、7、8、9、10、11、12、14
3525V 21、25、30、32、35、
38、45
10、12、14、15、17、19、21、25
4520V 42、45、50、57、60、
66、75
2、3、4、5、6、7、8、9、10、11、12、14
4525V 42、45、50、57、60、
66、75
10、12、14、15、17、19、21、25
4535V 42、45、50、57、60、
66、75
21、25、30、32、35、38、45

▽Usgpm Flow(Usgpm) at 1200r/min and 0.69MPa

Outlet Positions (Viewed from cover end of pump)
Outlet positions All series except 4535V 4535V
No. 1 outlet opposite inlet  AA No. 2 outlet 135° CCW from inlet  No. 2 outlet opposite inlet 
AB No. 2 outlet 45° CCW from inlet  No. 2 outlet 90° CCW from inlet 
AC No. 2 outlet 45° CW from inlet  No. 2 outlet inline with inlet 
AD No. 2 outlet 135° CW from inlet  No. 2 outlet 90° CW from inlet 
No. 1 outlet 90° CCW from inlet  BA No. 2 outlet 135° CCW from inlet  No. 2 outlet opposite inlet 
BB No. 2 outlet 45° CCW from inlet  No. 2 outlet 90° CCW from inlet 
BC No. 2 outlet 45° CW from inlet  No. 2 outlet inline with inlet 
BD No. 2 outlet 135° CW from inlet  No. 2 outlet 90° CW from inlet 

 

Outlet positions All series except 4535V 4535V
No. 1 outlet inline with inlet  CA No. 2 outlet 135° CCW from inlet  No. 2 outlet opposite inlet 
CB No. 2 outlet 45° CCW from inlet  No. 2 outlet 90° CCW from inlet 
CC No. 2 outlet 45° CW from inlet  No. 2 outlet inline with inlet 
CD No. 2 outlet 135° CW from inlet  No. 2 outlet 90° CW from inlet 
No. 1 outlet 90° CW from inlet  DA No. 2 outlet 135° CCW from inlet  No. 2 outlet opposite inlet 
DB No. 2 outlet 45° CCW from inlet  No. 2 outlet 90° CCW from inlet 
DC No. 2 outlet 45° CW from inlet  No. 2 outlet inline with inlet 
DD No. 2 outlet 135° CW from inlet  No. 2 outlet 90° CW from inlet

Product detail pictures:

Factory Outlets VQ Series  Double Pump Wholesale to Frankfurt detail pictures

Factory Outlets VQ Series  Double Pump Wholesale to Frankfurt detail pictures

Factory Outlets VQ Series  Double Pump Wholesale to Frankfurt detail pictures


Related Product Guide:
Why every website owner needs Google Analytics

We have now our possess revenue group, design staff, technical crew, QC team and package group. We now have strict excellent regulate procedures for each process. Also, all of our workers are experienced in printing subject for Factory Outlets VQ Series Double Pump Wholesale to Frankfurt, The product will supply to all over the world, such as: Barbados, Hyderabad, Greenland, Welcome any of your inquiries and concerns for our products. We look forward to establishing a long-term business relationship with you in the near future. Contact us today. We are the first business partner for you!
  • The factory workers have rich industry knowledge and operational experience, we learned a lot in working with them,we are extremely grateful that we can encount a good company has excellent wokers.
    5 Stars By Ryan from Brasilia - 2017.10.27 12:12
    Superb technology, perfect after-sales service and efficient work efficiency, we think this is our best choice.
    5 Stars By Renee from European - 2018.06.30 17:29
    Write your message here and send it to us

    Related Products

    WhatsApp Online Chat !