OEM Manufacturer VQ Series Double Pump to Palestine Factories

Short Description:

  Product Introduction The High-pressure and high-performance Intra-vane pumps for Mobile Equipmen Features 1.To adopt balanced hydraulic for the structure of Intra-vane and ten –Vane design, higher pressure, top to 21 MPa.2.To adopt floating structure for side plate, it will do a compensation for end-face clearance by automatic, so that even the pump under high pressure it can maintain a high volumetric efficiency. 3.The side plate is made of dual-metal material, it improved ...


Product Detail

Product Tags

Related Video

Feedback (2)

Our progress depends about the advanced products ,fantastic talents and continuously strengthened technology forces for Vickers Hydraulic Pump Repair Manual, Hydraulic Pump Jet, Vickers Hydraulic Pump Dealers In Hyderabad, All products and solutions arrive with high quality and fantastic after-sales expert services. Market-oriented and customer-oriented are what we now have been being immediately after. Sincerely look ahead to Win-Win cooperation !
OEM Manufacturer VQ Series Double Pump to Palestine Factories Detail:

 

Product Introduction

The High-pressure and high-performance Intra-vane pumps for Mobile Equipmen

Features

1.To adopt balanced hydraulic for the structure of Intra-vane and ten –Vane design, higher pressure, top to 21 MPa.
2.To adopt floating structure for side plate, it will do a compensation for end-face clearance by automatic, so that even the pump under high pressure it can maintain a high volumetric efficiency.
3.The side plate is made of dual-metal material, it improved the seizure resistance, and so that the life of pump will be longer.

VQ Series Double Pump

NO. Part Qty NO. Part Qty NO. Part Qty
1 Straight Key  1 7 Cir Clip For   Shaft  1 13 Rear Cartridge  1
2 Shaft 1 8 Pile Type   Retainer  1 14 O Ring  1
3 Front Cover  1 9 O Ring  1 15 Rear Cartridge  1
4 Shaft Seal  1 10 Front Cartridge  1 16 Hexagon Headed   Bolt  4
5 Gasket  1 11 Body  1
6 Ball Bearing  1 12 Hexagon Headed   Bolt  4

Model Designation

(F3-) 3525V  38 A 17 -1 AB 22 R
Note  Series ▼ Flow-Shaft end pump Port 
connection 
▼ Flow-cover 

end pump

Shaft type  Outlet
 Position 
Design 
number 
Rotation 
No-marking: 

Petroleum series oil

emulsification fluid

water glycol-fluid
F3:

phosphate
ester fluid 

2520V 10、12、14、15、17、
19、21、25
A-SAE
A-SAE 4-bolt flange
2、3、4、5、6、7、8、9、10、11、12、14 1-Str key
86-HD Str key
11-Spline
See below  22 (Views from shaft end of pump)
R-right hand for clockwise 
L-left hand for counter-clockwise
3520V 21、25、30、32、35、
38、45
2、3、4、5、6、7、8、9、10、11、12、14
3525V 21、25、30、32、35、
38、45
10、12、14、15、17、19、21、25
4520V 42、45、50、57、60、
66、75
2、3、4、5、6、7、8、9、10、11、12、14
4525V 42、45、50、57、60、
66、75
10、12、14、15、17、19、21、25
4535V 42、45、50、57、60、
66、75
21、25、30、32、35、38、45

▽Usgpm Flow(Usgpm) at 1200r/min and 0.69MPa

Outlet Positions (Viewed from cover end of pump)
Outlet positions All series except 4535V 4535V
No. 1 outlet opposite inlet  AA No. 2 outlet 135° CCW from inlet  No. 2 outlet opposite inlet 
AB No. 2 outlet 45° CCW from inlet  No. 2 outlet 90° CCW from inlet 
AC No. 2 outlet 45° CW from inlet  No. 2 outlet inline with inlet 
AD No. 2 outlet 135° CW from inlet  No. 2 outlet 90° CW from inlet 
No. 1 outlet 90° CCW from inlet  BA No. 2 outlet 135° CCW from inlet  No. 2 outlet opposite inlet 
BB No. 2 outlet 45° CCW from inlet  No. 2 outlet 90° CCW from inlet 
BC No. 2 outlet 45° CW from inlet  No. 2 outlet inline with inlet 
BD No. 2 outlet 135° CW from inlet  No. 2 outlet 90° CW from inlet 

 

Outlet positions All series except 4535V 4535V
No. 1 outlet inline with inlet  CA No. 2 outlet 135° CCW from inlet  No. 2 outlet opposite inlet 
CB No. 2 outlet 45° CCW from inlet  No. 2 outlet 90° CCW from inlet 
CC No. 2 outlet 45° CW from inlet  No. 2 outlet inline with inlet 
CD No. 2 outlet 135° CW from inlet  No. 2 outlet 90° CW from inlet 
No. 1 outlet 90° CW from inlet  DA No. 2 outlet 135° CCW from inlet  No. 2 outlet opposite inlet 
DB No. 2 outlet 45° CCW from inlet  No. 2 outlet 90° CCW from inlet 
DC No. 2 outlet 45° CW from inlet  No. 2 outlet inline with inlet 
DD No. 2 outlet 135° CW from inlet  No. 2 outlet 90° CW from inlet

Product detail pictures:

OEM Manufacturer VQ Series  Double Pump to Palestine Factories detail pictures

OEM Manufacturer VQ Series  Double Pump to Palestine Factories detail pictures

OEM Manufacturer VQ Series  Double Pump to Palestine Factories detail pictures


Related Product Guide:
Why every website owner needs Google Analytics

We usually perform being a tangible workforce making sure that we will give you the most beneficial excellent plus the finest selling price for OEM Manufacturer VQ Series Double Pump to Palestine Factories, The product will supply to all over the world, such as: Afghanistan, Portugal, Israel, Our team knows well the market demands in different countries, and is capable of supplying suitable quality products and solutions at the best prices to different markets. Our company has already set up a experienced, creative and responsible team to develop clients with the multi-win principle.
  • We feel easy to cooperate with this company, the supplier is very responsible, thanks.There will be more in-depth cooperation.
    5 Stars By Jeff Wolfe from Lisbon - 2018.12.28 15:18
    We have been cooperated with this company for many years, the company always ensure timely delivery ,good quality and correct number, we are good partners.
    5 Stars By Miriam from Congo - 2017.03.28 12:22

    Related Products

    WhatsApp Online Chat !