  Product Introduction The High-pressure and high-performance Intra-vane pumps for Mobile Equipmen Features 1.To adopt balanced hydraulic for the structure of Intra-vane and ten –Vane design, higher pressure, top to 21 MPa.2.To adopt floating structure for side plate, it will do a compensation for end-face clearance by automatic, so that even the pump under high pressure it can maintain a high volumetric efficiency. 3.The side plate is made of dual-metal material, it improved ...


Product Detail

Product Tags

Related Video

Feedback (2)

Our primary purpose is to give our shoppers a serious and responsible company relationship, giving personalized attention to all of them for Rule Bilge Pump Cartridge , Displacement Pump Basic Action , Denison Single Vane Pump , Because we stay in this line about 10 years. We got best suppliers support on quality and price. And we had weed out suppliers with poor quality. Now many OEM factories cooperated with us too.
Manufactur standard VQ Series Double Pump to Las Vegas Factories Detail:

 

Product Introduction

The High-pressure and high-performance Intra-vane pumps for Mobile Equipmen

Features

1.To adopt balanced hydraulic for the structure of Intra-vane and ten –Vane design, higher pressure, top to 21 MPa.
2.To adopt floating structure for side plate, it will do a compensation for end-face clearance by automatic, so that even the pump under high pressure it can maintain a high volumetric efficiency.
3.The side plate is made of dual-metal material, it improved the seizure resistance, and so that the life of pump will be longer.

VQ Series Double Pump

NO. Part Qty NO. Part Qty NO. Part Qty
1 Straight Key  1 7 Cir Clip For   Shaft  1 13 Rear Cartridge  1
2 Shaft 1 8 Pile Type   Retainer  1 14 O Ring  1
3 Front Cover  1 9 O Ring  1 15 Rear Cartridge  1
4 Shaft Seal  1 10 Front Cartridge  1 16 Hexagon Headed   Bolt  4
5 Gasket  1 11 Body  1
6 Ball Bearing  1 12 Hexagon Headed   Bolt  4

Model Designation

(F3-) 3525V  38 A 17 -1 AB 22 R
Note  Series ▼ Flow-Shaft end pump Port 
connection 
▼ Flow-cover 

end pump

Shaft type  Outlet
 Position 
Design 
number 
Rotation 
No-marking: 

Petroleum series oil

emulsification fluid

water glycol-fluid
F3:

phosphate
ester fluid 

2520V 10、12、14、15、17、
19、21、25
A-SAE
A-SAE 4-bolt flange
2、3、4、5、6、7、8、9、10、11、12、14 1-Str key
86-HD Str key
11-Spline
See below  22 (Views from shaft end of pump)
R-right hand for clockwise 
L-left hand for counter-clockwise
3520V 21、25、30、32、35、
38、45
2、3、4、5、6、7、8、9、10、11、12、14
3525V 21、25、30、32、35、
38、45
10、12、14、15、17、19、21、25
4520V 42、45、50、57、60、
66、75
2、3、4、5、6、7、8、9、10、11、12、14
4525V 42、45、50、57、60、
66、75
10、12、14、15、17、19、21、25
4535V 42、45、50、57、60、
66、75
21、25、30、32、35、38、45

▽Usgpm Flow(Usgpm) at 1200r/min and 0.69MPa

Outlet Positions (Viewed from cover end of pump)
Outlet positions All series except 4535V 4535V
No. 1 outlet opposite inlet  AA No. 2 outlet 135° CCW from inlet  No. 2 outlet opposite inlet 
AB No. 2 outlet 45° CCW from inlet  No. 2 outlet 90° CCW from inlet 
AC No. 2 outlet 45° CW from inlet  No. 2 outlet inline with inlet 
AD No. 2 outlet 135° CW from inlet  No. 2 outlet 90° CW from inlet 
No. 1 outlet 90° CCW from inlet  BA No. 2 outlet 135° CCW from inlet  No. 2 outlet opposite inlet 
BB No. 2 outlet 45° CCW from inlet  No. 2 outlet 90° CCW from inlet 
BC No. 2 outlet 45° CW from inlet  No. 2 outlet inline with inlet 
BD No. 2 outlet 135° CW from inlet  No. 2 outlet 90° CW from inlet 

 

Outlet positions All series except 4535V 4535V
No. 1 outlet inline with inlet  CA No. 2 outlet 135° CCW from inlet  No. 2 outlet opposite inlet 
CB No. 2 outlet 45° CCW from inlet  No. 2 outlet 90° CCW from inlet 
CC No. 2 outlet 45° CW from inlet  No. 2 outlet inline with inlet 
CD No. 2 outlet 135° CW from inlet  No. 2 outlet 90° CW from inlet 
No. 1 outlet 90° CW from inlet  DA No. 2 outlet 135° CCW from inlet  No. 2 outlet opposite inlet 
DB No. 2 outlet 45° CCW from inlet  No. 2 outlet 90° CCW from inlet 
DC No. 2 outlet 45° CW from inlet  No. 2 outlet inline with inlet 
DD No. 2 outlet 135° CW from inlet  No. 2 outlet 90° CW from inlet

Product detail pictures:

Manufactur standard
 VQ Series  Double Pump to Las Vegas Factories detail pictures

Manufactur standard
 VQ Series  Double Pump to Las Vegas Factories detail pictures

Manufactur standard
 VQ Series  Double Pump to Las Vegas Factories detail pictures


Related Product Guide:
Why every website owner needs Google Analytics

To create more benefit for buyers is our business philosophy; shopper growing is our working chase for Manufactur standard VQ Series Double Pump to Las Vegas Factories, The product will supply to all over the world, such as: Cape Town , Durban , Austria , We are looking forward to cooperating closely with you to our mutual benefits and top development. We guaranteed quality, if customers were not satisfied with the products' quality, you can return within 7days with their original states.
  • The company's products can meet our diverse needs, and the price is cheap, the most important is that the quality is also very nice.
    5 Stars By Ina from New Delhi - 2017.10.27 12:12
    A good manufacturers, we have cooperated twice, good quality and good service attitude.
    5 Stars By Irma from Luxemburg - 2018.11.06 10:04

    Related Products

    WhatsApp Online Chat !