Technical Data
| 460V | Frame | C | D | E0 | E3 | E2 | |||||||||
| Model Number VFD-___VL43_-J | 055A | 075A | 110A | 150B | 185B | 220A | 300B | 370B | 450B | 550A | 750A | ||||
| Power (kW) | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | ||||
| Horsepower (HP) | 7.5 | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 75 | 100 | ||||
| Output | Max. Current (A) (continuous 60 seconds ) | 21 | 27 | 36 | 46 | 58 | 62 | 102 | 124 | 155 | 187 | 255 | |||
| Max. Current (A) (continuous 20 seconds ) | 25 | 32 | 42 | 54 | 68 | 78 | 120 | 146 | 182 | 220 | 300 | ||||
| Input Current (A) | 14 | 18 | 24 | 31 | 39 | 47 | 56 | 67 | 87 | 101 | 122 | ||||
| Power | Input Voltage Tolerance | 3-Phase 380~480V, 50/60 Hz | |||||||||||||
| Mains Voltage Tolerance | ±10% (342-528V) | ||||||||||||||
| Mains Frequency Tolerance | ±5% (47-63Hz) | ||||||||||||||
| Weight (kg) | 8 | 10 | 10 | 10 | 10 | 13 | 13 | 28 | 36 | 50 | 50 | ||||
| General Specifications | Control Method | SVPWM | |||||||||||||
| Speed Detector | Resolver | ||||||||||||||
| Speed Input Command | DC 0~10V, support 3-point adjustment for analog inputs | ||||||||||||||
| Pressure Input Command | DC 0~10V, support 3-point adjustment for analog inputs | ||||||||||||||
| Pressure Feedback Command | DC 0~10V | ||||||||||||||
| General Input Signal | 5 ch DC24V 8mA | ||||||||||||||
| General Output Signal | 2 ch DC24V 50mA, 1 ch Relay output | ||||||||||||||
| Analog Output Voltage | 1 ch dc 0~10V | ||||||||||||||
| Optional Accessories | Speed Feedback PGA Card | Necessary (EMVJ-PG01R) | |||||||||||||
| Brake Resistor | Necessary (refer to appendix A) | ||||||||||||||
| Pressure Sensor | Necessray, only pressure sensors with output signal 0~10V can be used ( max. pressure value can be set by Pr. 00~08) | ||||||||||||||
| EMI Filter | Optional ( refer to Appendix A) | ||||||||||||||
| Protections | Motor Protection | Electronic thremal relay protection | |||||||||||||
| Over-current | 300% of rated current | ||||||||||||||
| Ground leakage current | Higher than 50% rated current | ||||||||||||||
| Voltage Protection | Over-voltage Level: Vdc>400/800V; Low-voltage Level: Vdc<200/400V | ||||||||||||||
| Mains Input Over-Voltage | Varistor (MOV) | ||||||||||||||
| Over-temperature | Built-in Temperature Sensor | ||||||||||||||
| Environment | Protection Level | NEMA 1/IP20 | |||||||||||||
| Operation Temperature | -10℃~45℃ | ||||||||||||||
| Storage Temperature | -20℃~60℃ | ||||||||||||||
| Humidity | 90% RH (non-condensing) | ||||||||||||||
| Vibration | 1.0G 20Hz, 20~60Hz 0.6G <20Hz: 1.0G, 20 to 60 Hz: 0.6G | ||||||||||||||
| Cooling System | (RUN, STOP) Force cooling (RUN, STOP) | ||||||||||||||
| Installation Location | Altitude 1,000m or lower (keep away from corrosive gasses, liquid and dust) | ||||||||||||||
| Certifications | CE | ||||||||||||||
Note: Bulit in brake chopper for models 22kw and below
Product detail pictures:

Related Product Guide:
Why every website owner needs Google Analytics
Having a positive and progressive attitude to customer's fascination, our organization constantly improves our solution high-quality to fulfill the requirements of shoppers and further focuses on safety, reliability, environmental prerequisites, and innovation of Good Quality Vicks Servo Drive Taiwan Delta Export to Naples, The product will supply to all over the world, such as: Auckland , Czech Republic , Cairo , We focus on providing service for our clients as a key element in strengthening our long-term relationships. Our continual availability of high grade products in combination with our excellent pre-sale and after-sales service ensures strong competitiveness in an increasingly globalized market.