Factory Supply VQ Series Double Pump Supply to Bogota

Factory Supply VQ Series  Double Pump Supply to Bogota Featured Image
Loading...

Short Description:

  Product Introduction The High-pressure and high-performance Intra-vane pumps for Mobile Equipmen Features 1.To adopt balanced hydraulic for the structure of Intra-vane and ten –Vane design, higher pressure, top to 21 MPa.2.To adopt floating structure for side plate, it will do a compensation for end-face clearance by automatic, so that even the pump under high pressure it can maintain a high volumetric efficiency. 3.The side plate is made of dual-metal material, it improved ...


Product Detail

Product Tags

Related Video

Feedback (2)

We provide fantastic energy in top quality and advancement,merchandising,gross sales and marketing and operation for Electric Over Hydraulic Pump Kit, Vickers Vane Pump Log Splitter, Hydraulic Pump Information, Living by quality, development by credit is our eternal pursuit, We firmly believe that after your visit we will become long-term partners.
Factory Supply VQ Series Double Pump Supply to Bogota Detail:

 

Product Introduction

The High-pressure and high-performance Intra-vane pumps for Mobile Equipmen

Features

1.To adopt balanced hydraulic for the structure of Intra-vane and ten –Vane design, higher pressure, top to 21 MPa.
2.To adopt floating structure for side plate, it will do a compensation for end-face clearance by automatic, so that even the pump under high pressure it can maintain a high volumetric efficiency.
3.The side plate is made of dual-metal material, it improved the seizure resistance, and so that the life of pump will be longer.

VQ Series Double Pump

NO. Part Qty NO. Part Qty NO. Part Qty
1 Straight Key  1 7 Cir Clip For   Shaft  1 13 Rear Cartridge  1
2 Shaft 1 8 Pile Type   Retainer  1 14 O Ring  1
3 Front Cover  1 9 O Ring  1 15 Rear Cartridge  1
4 Shaft Seal  1 10 Front Cartridge  1 16 Hexagon Headed   Bolt  4
5 Gasket  1 11 Body  1
6 Ball Bearing  1 12 Hexagon Headed   Bolt  4

Model Designation

(F3-) 3525V  38 A 17 -1 AB 22 R
Note  Series ▼ Flow-Shaft end pump Port 
connection 
▼ Flow-cover 

end pump

Shaft type  Outlet
 Position 
Design 
number 
Rotation 
No-marking: 

Petroleum series oil

emulsification fluid

water glycol-fluid
F3:

phosphate
ester fluid 

2520V 10、12、14、15、17、
19、21、25
A-SAE
A-SAE 4-bolt flange
2、3、4、5、6、7、8、9、10、11、12、14 1-Str key
86-HD Str key
11-Spline
See below  22 (Views from shaft end of pump)
R-right hand for clockwise 
L-left hand for counter-clockwise
3520V 21、25、30、32、35、
38、45
2、3、4、5、6、7、8、9、10、11、12、14
3525V 21、25、30、32、35、
38、45
10、12、14、15、17、19、21、25
4520V 42、45、50、57、60、
66、75
2、3、4、5、6、7、8、9、10、11、12、14
4525V 42、45、50、57、60、
66、75
10、12、14、15、17、19、21、25
4535V 42、45、50、57、60、
66、75
21、25、30、32、35、38、45

▽Usgpm Flow(Usgpm) at 1200r/min and 0.69MPa

Outlet Positions (Viewed from cover end of pump)
Outlet positions All series except 4535V 4535V
No. 1 outlet opposite inlet  AA No. 2 outlet 135° CCW from inlet  No. 2 outlet opposite inlet 
AB No. 2 outlet 45° CCW from inlet  No. 2 outlet 90° CCW from inlet 
AC No. 2 outlet 45° CW from inlet  No. 2 outlet inline with inlet 
AD No. 2 outlet 135° CW from inlet  No. 2 outlet 90° CW from inlet 
No. 1 outlet 90° CCW from inlet  BA No. 2 outlet 135° CCW from inlet  No. 2 outlet opposite inlet 
BB No. 2 outlet 45° CCW from inlet  No. 2 outlet 90° CCW from inlet 
BC No. 2 outlet 45° CW from inlet  No. 2 outlet inline with inlet 
BD No. 2 outlet 135° CW from inlet  No. 2 outlet 90° CW from inlet 

 

Outlet positions All series except 4535V 4535V
No. 1 outlet inline with inlet  CA No. 2 outlet 135° CCW from inlet  No. 2 outlet opposite inlet 
CB No. 2 outlet 45° CCW from inlet  No. 2 outlet 90° CCW from inlet 
CC No. 2 outlet 45° CW from inlet  No. 2 outlet inline with inlet 
CD No. 2 outlet 135° CW from inlet  No. 2 outlet 90° CW from inlet 
No. 1 outlet 90° CW from inlet  DA No. 2 outlet 135° CCW from inlet  No. 2 outlet opposite inlet 
DB No. 2 outlet 45° CCW from inlet  No. 2 outlet 90° CCW from inlet 
DC No. 2 outlet 45° CW from inlet  No. 2 outlet inline with inlet 
DD No. 2 outlet 135° CW from inlet  No. 2 outlet 90° CW from inlet

Product detail pictures:

Factory Supply VQ Series  Double Pump Supply to Bogota detail pictures

Factory Supply VQ Series  Double Pump Supply to Bogota detail pictures

Factory Supply VQ Series  Double Pump Supply to Bogota detail pictures


Related Product Guide:
Why every website owner needs Google Analytics

We keep on with our business spirit of "Quality, Performance, Innovation and Integrity". We goal to create much more worth for our customers with our rich resources, state-of-the-art machinery, experienced workers and exceptional providers for Factory Supply VQ Series Double Pump Supply to Bogota, The product will supply to all over the world, such as: French, Russia, Ukraine, we have all day online sales to make sure the pre-sale and after-sale service in time. With all these supports, we can serve every customer with quality product and timely shipping with highly responsibility. Being a young growing company, we might not the best, but we are trying our best to be your good partner.
  • In China, we have many partners, this company is the most satisfying to us, reliable quality and good credit, it is worth appreciation.
    5 Stars By Agnes from New York - 2017.06.29 18:55
    This supplier stick to the principle of "Quality first, Honesty as base", it is absolutely to be trust.
    5 Stars By Laurel from Ukraine - 2018.06.19 10:42
    Write your message here and send it to us

    Related Products

    WhatsApp Online Chat !