Factory selling Vicks Servo Drive Taiwan Delta to Ecuador Factories
Factory selling Vicks Servo Drive Taiwan Delta to Ecuador Factories Detail:
Vicks Servo System Delta Drive
Technical Data
460V | Frame | C | D | E0 | E3 | E2 | |||||||||
Model Number VFD-___VL43_-J | 055A | 075A | 110A | 150B | 185B | 220A | 300B | 370B | 450B | 550A | 750A | ||||
Power (kW) | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | ||||
Horsepower (HP) | 7.5 | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 75 | 100 | ||||
Output | Max. Current (A) (continuous 60 seconds ) | 21 | 27 | 36 | 46 | 58 | 62 | 102 | 124 | 155 | 187 | 255 | |||
Max. Current (A) (continuous 20 seconds ) | 25 | 32 | 42 | 54 | 68 | 78 | 120 | 146 | 182 | 220 | 300 | ||||
Input Current (A) | 14 | 18 | 24 | 31 | 39 | 47 | 56 | 67 | 87 | 101 | 122 | ||||
Power | Input Voltage Tolerance | 3-Phase 380~480V, 50/60 Hz | |||||||||||||
Mains Voltage Tolerance | ±10% (342-528V) | ||||||||||||||
Mains Frequency Tolerance | ±5% (47-63Hz) | ||||||||||||||
Weight (kg) | 8 | 10 | 10 | 10 | 10 | 13 | 13 | 28 | 36 | 50 | 50 | ||||
General Specifications | Control Method | SVPWM | |||||||||||||
Speed Detector | Resolver | ||||||||||||||
Speed Input Command | DC 0~10V, support 3-point adjustment for analog inputs | ||||||||||||||
Pressure Input Command | DC 0~10V, support 3-point adjustment for analog inputs | ||||||||||||||
Pressure Feedback Command | DC 0~10V | ||||||||||||||
General Input Signal | 5 ch DC24V 8mA | ||||||||||||||
General Output Signal | 2 ch DC24V 50mA, 1 ch Relay output | ||||||||||||||
Analog Output Voltage | 1 ch dc 0~10V | ||||||||||||||
Optional Accessories | Speed Feedback PGA Card | Necessary (EMVJ-PG01R) | |||||||||||||
Brake Resistor | Necessary (refer to appendix A) | ||||||||||||||
Pressure Sensor | Necessray, only pressure sensors with output signal 0~10V can be used ( max. pressure value can be set by Pr. 00~08) | ||||||||||||||
EMI Filter | Optional ( refer to Appendix A) | ||||||||||||||
Protections | Motor Protection | Electronic thremal relay protection | |||||||||||||
Over-current | 300% of rated current | ||||||||||||||
Ground leakage current | Higher than 50% rated current | ||||||||||||||
Voltage Protection | Over-voltage Level: Vdc>400/800V; Low-voltage Level: Vdc<200/400V | ||||||||||||||
Mains Input Over-Voltage | Varistor (MOV) | ||||||||||||||
Over-temperature | Built-in Temperature Sensor | ||||||||||||||
Environment | Protection Level | NEMA 1/IP20 | |||||||||||||
Operation Temperature | -10℃~45℃ | ||||||||||||||
Storage Temperature | -20℃~60℃ | ||||||||||||||
Humidity | 90% RH (non-condensing) | ||||||||||||||
Vibration | 1.0G 20Hz, 20~60Hz 0.6G <20Hz: 1.0G, 20 to 60 Hz: 0.6G | ||||||||||||||
Cooling System | (RUN, STOP) Force cooling (RUN, STOP) | ||||||||||||||
Installation Location | Altitude 1,000m or lower (keep away from corrosive gasses, liquid and dust) | ||||||||||||||
Certifications | CE |
Note: Bulit in brake chopper for models 22kw and below
Product detail pictures:

Related Product Guide:
Why every website owner needs Google Analytics
"Control the quality by the details, show the strength by quality". Our company has strived to establish a highly efficient and stable staff team and explored an effective quality control process for Factory selling Vicks Servo Drive Taiwan Delta to Ecuador Factories, The product will supply to all over the world, such as: Costa Rica, Manila, Montreal, With a team of experienced and knowledgeable personnel, our market covers South America, the USA, the Mid East, and North Africa. Many customers have become our friends after good cooperation with us. If you have the requirement for any of our products, please contact us now. We are looking forward to hearing from you soon.