factory customized Vicks Servo Drive Taiwan Delta to Macedonia Factories
factory customized Vicks Servo Drive Taiwan Delta to Macedonia Factories Detail:
Vicks Servo System Delta Drive

Technical Data
| 460V | Frame | C | D | E0 | E3 | E2 | |||||||||
| Model Number VFD-___VL43_-J | 055A | 075A | 110A | 150B | 185B | 220A | 300B | 370B | 450B | 550A | 750A | ||||
| Power (kW) | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | ||||
| Horsepower (HP) | 7.5 | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 75 | 100 | ||||
| Output | Max. Current (A) (continuous 60 seconds ) | 21 | 27 | 36 | 46 | 58 | 62 | 102 | 124 | 155 | 187 | 255 | |||
| Max. Current (A) (continuous 20 seconds ) | 25 | 32 | 42 | 54 | 68 | 78 | 120 | 146 | 182 | 220 | 300 | ||||
| Input Current (A) | 14 | 18 | 24 | 31 | 39 | 47 | 56 | 67 | 87 | 101 | 122 | ||||
| Power | Input Voltage Tolerance | 3-Phase 380~480V, 50/60 Hz | |||||||||||||
| Mains Voltage Tolerance | ±10% (342-528V) | ||||||||||||||
| Mains Frequency Tolerance | ±5% (47-63Hz) | ||||||||||||||
| Weight (kg) | 8 | 10 | 10 | 10 | 10 | 13 | 13 | 28 | 36 | 50 | 50 | ||||
| General Specifications | Control Method | SVPWM | |||||||||||||
| Speed Detector | Resolver | ||||||||||||||
| Speed Input Command | DC 0~10V, support 3-point adjustment for analog inputs | ||||||||||||||
| Pressure Input Command | DC 0~10V, support 3-point adjustment for analog inputs | ||||||||||||||
| Pressure Feedback Command | DC 0~10V | ||||||||||||||
| General Input Signal | 5 ch DC24V 8mA | ||||||||||||||
| General Output Signal | 2 ch DC24V 50mA, 1 ch Relay output | ||||||||||||||
| Analog Output Voltage | 1 ch dc 0~10V | ||||||||||||||
| Optional Accessories | Speed Feedback PGA Card | Necessary (EMVJ-PG01R) | |||||||||||||
| Brake Resistor | Necessary (refer to appendix A) | ||||||||||||||
| Pressure Sensor | Necessray, only pressure sensors with output signal 0~10V can be used ( max. pressure value can be set by Pr. 00~08) | ||||||||||||||
| EMI Filter | Optional ( refer to Appendix A) | ||||||||||||||
| Protections | Motor Protection | Electronic thremal relay protection | |||||||||||||
| Over-current | 300% of rated current | ||||||||||||||
| Ground leakage current | Higher than 50% rated current | ||||||||||||||
| Voltage Protection | Over-voltage Level: Vdc>400/800V; Low-voltage Level: Vdc<200/400V | ||||||||||||||
| Mains Input Over-Voltage | Varistor (MOV) | ||||||||||||||
| Over-temperature | Built-in Temperature Sensor | ||||||||||||||
| Environment | Protection Level | NEMA 1/IP20 | |||||||||||||
| Operation Temperature | -10℃~45℃ | ||||||||||||||
| Storage Temperature | -20℃~60℃ | ||||||||||||||
| Humidity | 90% RH (non-condensing) | ||||||||||||||
| Vibration | 1.0G 20Hz, 20~60Hz 0.6G <20Hz: 1.0G, 20 to 60 Hz: 0.6G | ||||||||||||||
| Cooling System | (RUN, STOP) Force cooling (RUN, STOP) | ||||||||||||||
| Installation Location | Altitude 1,000m or lower (keep away from corrosive gasses, liquid and dust) | ||||||||||||||
| Certifications | CE | ||||||||||||||
Note: Bulit in brake chopper for models 22kw and below
Product detail pictures:

Related Product Guide:
Why every website owner needs Google Analytics
owing to excellent assistance, a variety of top of the range items, aggressive costs and efficient delivery, we take pleasure in a very good standing amongst our shoppers. We've been an energetic corporation with wide market for factory customized Vicks Servo Drive Taiwan Delta to Macedonia Factories, The product will supply to all over the world, such as: Auckland, Slovak Republic, Palestine, Now the competition in this field is very fierce; but we will still offer best quality, reasonable price and most considerate service in an endeavor to achieve win-win goal. "Change for the better!" is our slogan, which means "A better world is before us, so let's enjoy it!" Change for the better! Are you ready?
The manufacturer gave us a big discount under the premise of ensuring the quality of products, thank you very much, we will select this company again.