Europe style for Vicks Servo Drive Taiwan Delta for San Diego Importers
Europe style for Vicks Servo Drive Taiwan Delta for San Diego Importers Detail:
Vicks Servo System Delta Drive

Technical Data
| 460V | Frame | C | D | E0 | E3 | E2 | |||||||||
| Model Number VFD-___VL43_-J | 055A | 075A | 110A | 150B | 185B | 220A | 300B | 370B | 450B | 550A | 750A | ||||
| Power (kW) | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | ||||
| Horsepower (HP) | 7.5 | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 75 | 100 | ||||
| Output | Max. Current (A) (continuous 60 seconds ) | 21 | 27 | 36 | 46 | 58 | 62 | 102 | 124 | 155 | 187 | 255 | |||
| Max. Current (A) (continuous 20 seconds ) | 25 | 32 | 42 | 54 | 68 | 78 | 120 | 146 | 182 | 220 | 300 | ||||
| Input Current (A) | 14 | 18 | 24 | 31 | 39 | 47 | 56 | 67 | 87 | 101 | 122 | ||||
| Power | Input Voltage Tolerance | 3-Phase 380~480V, 50/60 Hz | |||||||||||||
| Mains Voltage Tolerance | ±10% (342-528V) | ||||||||||||||
| Mains Frequency Tolerance | ±5% (47-63Hz) | ||||||||||||||
| Weight (kg) | 8 | 10 | 10 | 10 | 10 | 13 | 13 | 28 | 36 | 50 | 50 | ||||
| General Specifications | Control Method | SVPWM | |||||||||||||
| Speed Detector | Resolver | ||||||||||||||
| Speed Input Command | DC 0~10V, support 3-point adjustment for analog inputs | ||||||||||||||
| Pressure Input Command | DC 0~10V, support 3-point adjustment for analog inputs | ||||||||||||||
| Pressure Feedback Command | DC 0~10V | ||||||||||||||
| General Input Signal | 5 ch DC24V 8mA | ||||||||||||||
| General Output Signal | 2 ch DC24V 50mA, 1 ch Relay output | ||||||||||||||
| Analog Output Voltage | 1 ch dc 0~10V | ||||||||||||||
| Optional Accessories | Speed Feedback PGA Card | Necessary (EMVJ-PG01R) | |||||||||||||
| Brake Resistor | Necessary (refer to appendix A) | ||||||||||||||
| Pressure Sensor | Necessray, only pressure sensors with output signal 0~10V can be used ( max. pressure value can be set by Pr. 00~08) | ||||||||||||||
| EMI Filter | Optional ( refer to Appendix A) | ||||||||||||||
| Protections | Motor Protection | Electronic thremal relay protection | |||||||||||||
| Over-current | 300% of rated current | ||||||||||||||
| Ground leakage current | Higher than 50% rated current | ||||||||||||||
| Voltage Protection | Over-voltage Level: Vdc>400/800V; Low-voltage Level: Vdc<200/400V | ||||||||||||||
| Mains Input Over-Voltage | Varistor (MOV) | ||||||||||||||
| Over-temperature | Built-in Temperature Sensor | ||||||||||||||
| Environment | Protection Level | NEMA 1/IP20 | |||||||||||||
| Operation Temperature | -10℃~45℃ | ||||||||||||||
| Storage Temperature | -20℃~60℃ | ||||||||||||||
| Humidity | 90% RH (non-condensing) | ||||||||||||||
| Vibration | 1.0G 20Hz, 20~60Hz 0.6G <20Hz: 1.0G, 20 to 60 Hz: 0.6G | ||||||||||||||
| Cooling System | (RUN, STOP) Force cooling (RUN, STOP) | ||||||||||||||
| Installation Location | Altitude 1,000m or lower (keep away from corrosive gasses, liquid and dust) | ||||||||||||||
| Certifications | CE | ||||||||||||||
Note: Bulit in brake chopper for models 22kw and below
Product detail pictures:

Related Product Guide:
Why every website owner needs Google Analytics
We support our purchasers with ideal high-quality merchandise and significant level company. Becoming the specialist manufacturer in this sector, we now have received loaded practical encounter in producing and managing for Europe style for Vicks Servo Drive Taiwan Delta for San Diego Importers, The product will supply to all over the world, such as: Montpellier, Malaysia, Croatia, We are seeking the chances to meet all the friends from both at home and abroad for the win-win cooperation. We sincerely hope to have long-term cooperation with all of you on the bases of mutual benefit and common development.