Technical Data
460V | Frame | C | D | E0 | E3 | E2 | |||||||||
Model Number VFD-___VL43_-J | 055A | 075A | 110A | 150B | 185B | 220A | 300B | 370B | 450B | 550A | 750A | ||||
Power (kW) | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | ||||
Horsepower (HP) | 7.5 | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 75 | 100 | ||||
Output | Max. Current (A) (continuous 60 seconds ) | 21 | 27 | 36 | 46 | 58 | 62 | 102 | 124 | 155 | 187 | 255 | |||
Max. Current (A) (continuous 20 seconds ) | 25 | 32 | 42 | 54 | 68 | 78 | 120 | 146 | 182 | 220 | 300 | ||||
Input Current (A) | 14 | 18 | 24 | 31 | 39 | 47 | 56 | 67 | 87 | 101 | 122 | ||||
Power | Input Voltage Tolerance | 3-Phase 380~480V, 50/60 Hz | |||||||||||||
Mains Voltage Tolerance | ±10% (342-528V) | ||||||||||||||
Mains Frequency Tolerance | ±5% (47-63Hz) | ||||||||||||||
Weight (kg) | 8 | 10 | 10 | 10 | 10 | 13 | 13 | 28 | 36 | 50 | 50 | ||||
General Specifications | Control Method | SVPWM | |||||||||||||
Speed Detector | Resolver | ||||||||||||||
Speed Input Command | DC 0~10V, support 3-point adjustment for analog inputs | ||||||||||||||
Pressure Input Command | DC 0~10V, support 3-point adjustment for analog inputs | ||||||||||||||
Pressure Feedback Command | DC 0~10V | ||||||||||||||
General Input Signal | 5 ch DC24V 8mA | ||||||||||||||
General Output Signal | 2 ch DC24V 50mA, 1 ch Relay output | ||||||||||||||
Analog Output Voltage | 1 ch dc 0~10V | ||||||||||||||
Optional Accessories | Speed Feedback PGA Card | Necessary (EMVJ-PG01R) | |||||||||||||
Brake Resistor | Necessary (refer to appendix A) | ||||||||||||||
Pressure Sensor | Necessray, only pressure sensors with output signal 0~10V can be used ( max. pressure value can be set by Pr. 00~08) | ||||||||||||||
EMI Filter | Optional ( refer to Appendix A) | ||||||||||||||
Protections | Motor Protection | Electronic thremal relay protection | |||||||||||||
Over-current | 300% of rated current | ||||||||||||||
Ground leakage current | Higher than 50% rated current | ||||||||||||||
Voltage Protection | Over-voltage Level: Vdc>400/800V; Low-voltage Level: Vdc<200/400V | ||||||||||||||
Mains Input Over-Voltage | Varistor (MOV) | ||||||||||||||
Over-temperature | Built-in Temperature Sensor | ||||||||||||||
Environment | Protection Level | NEMA 1/IP20 | |||||||||||||
Operation Temperature | -10℃~45℃ | ||||||||||||||
Storage Temperature | -20℃~60℃ | ||||||||||||||
Humidity | 90% RH (non-condensing) | ||||||||||||||
Vibration | 1.0G 20Hz, 20~60Hz 0.6G <20Hz: 1.0G, 20 to 60 Hz: 0.6G | ||||||||||||||
Cooling System | (RUN, STOP) Force cooling (RUN, STOP) | ||||||||||||||
Installation Location | Altitude 1,000m or lower (keep away from corrosive gasses, liquid and dust) | ||||||||||||||
Certifications | CE |
Note: Bulit in brake chopper for models 22kw and below
Product detail pictures:

Related Product Guide:
Why every website owner needs Google Analytics
Every member from our high efficiency sales team values customers' needs and business communication for China Supplier Vicks Servo Drive Taiwan Delta for Los Angeles Manufacturers, The product will supply to all over the world, such as: venezuela, Iceland, Curacao, Our products and solutions are sold to the Middle East, Southeast Asia, Africa, Europe, America and other regions, and are favorably appraised by clients. To benefit from our strong OEM/ODM capabilities and considerate services, be sure to contact us today. We will sincerely create and share success with all clients.