Vicks Servo System Delta Drive
Technical Data
460V | Frame | C | D | E0 | E3 | E2 | |||||||||
Model Number VFD-___VL43_-J | 055A | 075A | 110A | 150B | 185B | 220A | 300B | 370B | 450B | 550A | 750A | ||||
Power (kW) | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | ||||
Horsepower (HP) | 7.5 | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 75 | 100 | ||||
Output | Max. Current (A) (continuous 60 seconds ) | 21 | 27 | 36 | 46 | 58 | 62 | 102 | 124 | 155 | 187 | 255 | |||
Max. Current (A) (continuous 20 seconds ) | 25 | 32 | 42 | 54 | 68 | 78 | 120 | 146 | 182 | 220 | 300 | ||||
Input Current (A) | 14 | 18 | 24 | 31 | 39 | 47 | 56 | 67 | 87 | 101 | 122 | ||||
Power | Input Voltage Tolerance | 3-Phase 380~480V, 50/60 Hz | |||||||||||||
Mains Voltage Tolerance | ±10% (342-528V) | ||||||||||||||
Mains Frequency Tolerance | ±5% (47-63Hz) | ||||||||||||||
Weight (kg) | 8 | 10 | 10 | 10 | 10 | 13 | 13 | 28 | 36 | 50 | 50 | ||||
General Specifications | Control Method | SVPWM | |||||||||||||
Speed Detector | Resolver | ||||||||||||||
Speed Input Command | DC 0~10V, support 3-point adjustment for analog inputs | ||||||||||||||
Pressure Input Command | DC 0~10V, support 3-point adjustment for analog inputs | ||||||||||||||
Pressure Feedback Command | DC 0~10V | ||||||||||||||
General Input Signal | 5 ch DC24V 8mA | ||||||||||||||
General Output Signal | 2 ch DC24V 50mA, 1 ch Relay output | ||||||||||||||
Analog Output Voltage | 1 ch dc 0~10V | ||||||||||||||
Optional Accessories | Speed Feedback PGA Card | Necessary (EMVJ-PG01R) | |||||||||||||
Brake Resistor | Necessary (refer to appendix A) | ||||||||||||||
Pressure Sensor | Necessray, only pressure sensors with output signal 0~10V can be used ( max. pressure value can be set by Pr. 00~08) | ||||||||||||||
EMI Filter | Optional ( refer to Appendix A) | ||||||||||||||
Protections | Motor Protection | Electronic thremal relay protection | |||||||||||||
Over-current | 300% of rated current | ||||||||||||||
Ground leakage current | Higher than 50% rated current | ||||||||||||||
Voltage Protection | Over-voltage Level: Vdc>400/800V; Low-voltage Level: Vdc<200/400V | ||||||||||||||
Mains Input Over-Voltage | Varistor (MOV) | ||||||||||||||
Over-temperature | Built-in Temperature Sensor | ||||||||||||||
Environment | Protection Level | NEMA 1/IP20 | |||||||||||||
Operation Temperature | -10℃~45℃ | ||||||||||||||
Storage Temperature | -20℃~60℃ | ||||||||||||||
Humidity | 90% RH (non-condensing) | ||||||||||||||
Vibration | 1.0G 20Hz, 20~60Hz 0.6G <20Hz: 1.0G, 20 to 60 Hz: 0.6G | ||||||||||||||
Cooling System | (RUN, STOP) Force cooling (RUN, STOP) | ||||||||||||||
Installation Location | Altitude 1,000m or lower (keep away from corrosive gasses, liquid and dust) | ||||||||||||||
Certifications | CE |
Note: Bulit in brake chopper for models 22kw and below
Product detail pictures:

Related Product Guide:
Why every website owner needs Google Analytics
We believe that prolonged time period partnership is really a result of top of the range, benefit added provider, prosperous knowledge and personal contact for China OEM Vicks Servo Drive Taiwan Delta to Sudan Factories, The product will supply to all over the world, such as: Macedonia, Kuwait, Boston, For more than ten years experience in this filed, our company has gained high reputation from home and abroad. So we welcome friends from all over the world to come and contact us, not only for business, but also for friendship.