Draibhear Servo Vicks Taiwan Delta Drive airson Inneal Molltair In-stealladh
Siostam Servo Vicks Delta Drive

Dàta Teicnigeach
| 460V | Frèam | C | D | E0 | E3 | E2 | |||||||||
| Àireamh a’ Mhodail VFD-___VL43_-J | 055A | 075A | 110A | 150B | 185B | 220A | 300B | 370B | 450B | 550A | 750A | ||||
| Cumhachd (kW) | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | ||||
| Each-chumhachd (HP) | 7.5 | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 75 | 100 | ||||
| Toradh | Sruth as àirde (A) (leantainneach 60 diogan) | 21 | 27 | 36 | 46 | 58 | 62 | 102 | 124 | 155 | 187 | 255 | |||
| Sruth as àirde (A) (leantainneach 20 diogan) | 25 | 32 | 42 | 54 | 68 | 78 | 120 | 146 | 182 | 220 | 300 | ||||
| Sruth Cuir-a-steach (A) | 14 | 18 | 24 | 31 | 39 | 47 | 56 | 67 | 87 | 101 | 122 | ||||
| Cumhachd | Fulangas Bholtaids Cuir a-steach | 3-Ìre 380~480V, 50/60 Hz | |||||||||||||
| Fulangas Bholtaids Prìomh-loidhne | ±10% (342-528V) | ||||||||||||||
| Fulangas Tricead Prìomh-loidhne | ±5% (47-63Hz) | ||||||||||||||
| Cuideam (kg) | 8 | 10 | 10 | 10 | 10 | 13 | 13 | 28 | 36 | 50 | 50 | ||||
| Sònrachaidhean Coitcheann | Modh Smachd | SVPWM | |||||||||||||
| Lorgaire Luas | Fuasgladh | ||||||||||||||
| Òrdugh Cuir a-steach Luas | DC 0 ~ 10V, taic ri atharrachadh 3-phuing airson cuir-a-steach analogach | ||||||||||||||
| Òrdugh Cuir a-steach Brùthadh | DC 0 ~ 10V, taic ri atharrachadh 3-phuing airson cuir-a-steach analogach | ||||||||||||||
| Òrdugh Aiseag Brùthaidh | DC 0~10V | ||||||||||||||
| Comharra Ion-chuir Coitcheann | 5 seanalan DC24V 8mA | ||||||||||||||
| Comharra Toraidh Coitcheann | 2 chànan DC24V 50mA, toradh ath-chraolaidh 1 chànan | ||||||||||||||
| Bholtaids Toraidh Analogach | 1 seanail dc 0~10V | ||||||||||||||
| Goireasan Roghainneil | Cairt PGA Luaths-aiseag | Riatanach (EMVJ-PG01R) | |||||||||||||
| Resistor Breic | Riatanach (faic leas-phàipear A) | ||||||||||||||
| Braitear Brùthaidh | Gu riatanach, chan urrainnear ach mothachairean cuideam le comharra toraidh 0~10V a chleachdadh (faodar an luach cuideam as àirde a shuidheachadh le Pr. 00~08) | ||||||||||||||
| Criathrag EMI | Roghainneil (faic Leas-phàipear A) | ||||||||||||||
| Dìonan | Dìon Motair | Dìon ath-chraolaidh thremal dealanach | |||||||||||||
| Cus-shruth | 300% den t-sruth reataichte | ||||||||||||||
| Sruth aodion talmhainn | Nas àirde na 50% den t-sruth ìreichte | ||||||||||||||
| Dìon Bholtaids | Ìre Thar-bholtaids: Vdc > 400/800V; Ìre Ìosal-bholtaids: Vdc < 200/400V | ||||||||||||||
| Cus-bholtaids Cuir-a-steach Prìomh-lìonra | Varistor (MOV) | ||||||||||||||
| Cus teòthachd | Braitear Teòthachd Togte a-steach | ||||||||||||||
| Àrainneachd | Ìre Dìon | NEMA 1/IP20 | |||||||||||||
| Teòthachd Obrachaidh | -10℃~45℃ | ||||||||||||||
| Teòthachd Stòraidh | -20℃~60℃ | ||||||||||||||
| Taiseachd | 90% RH (gun dùmhlachd) | ||||||||||||||
| Crith | 1.0G 20Hz, 20~60Hz 0.6G <20Hz: 1.0G, 20 gu 60 Hz: 0.6G | ||||||||||||||
| Siostam Fuarachaidh | (RUITH, STAD) Fuarachadh feachdail (RUITH, STAD) | ||||||||||||||
| Àite an Stàlaidh | Àirde 1,000m no nas ìsle (cùm air falbh bho ghasan creimneach, leaghan agus duslach) | ||||||||||||||
| Teisteanasan | CE | ||||||||||||||
Nota: Chopper breic togte a-steach airson modailean 22kw agus nas ìsle